Detailed Analysis of the Role of Termination Resistors in PROFIBUS-DP Connectors

PROFIBUS Physical Wiring and DP Connector Diagram From the diagram, it can be seen that when the switch is turned to “ON”, terminals A1 and B1 are connected to the termination resistor, so only A1 and B1 can be connected at the end of the DP network; otherwise, the termination resistor cannot be connected. When … Read more

Siemens Powerful Communication Features Every Expert Must Learn

Siemens All-Subject + TIA Portal + EPLAN Electrical Drawing Video Recordings for Sale at Low Prices! Chuangkong Education Siemens All-Subject Course Introduction When it comes to Siemens communication, we must mention PROFIBUS. Do you know what it is? How to use it? PROFIBUS supports master-slave mode and multi-master multi-slave mode. In the multi-master mode, the … Read more

Siemens S7-300 PLC and Modbus Communication DCS Control System Design

Click↑↑Technical Training, follow and pin to subscribe for free for a long time 180,000+ industrial control professionals are following the WeChat platform: technical sharing, learning exchange, industrial control videos This article introduces how to achieve communication between Modbus and Profibus-DP protocol devices, the application of the Modbus to Profibus-DP gateway PM-160, and the communication methods … Read more

Signal Exchange Between Multiple PLCs

Multiple How to Exchange Signals Between Multiple PLCs? Previously, I discussed that in some large smart factories, a single or multiple large PLCs usually form the processing core.The advantage of a single PLC is that all important equipment needs to be controlled by this unified core, allowing for high integration of information. However, large PLCs … Read more

MODBUS TCP Communication Between Schneider M580 and Siemens S7200 SMART

WeChat Search Technical Training The M580 is Schneider’s medium to large PLC, powerful in functionality, while the S7 200 SMART is Siemens’ small PLC, widely used in industrial settings where communication between two PLCs is often required. The M580 supports both MODBUS TCP and Ethernet/IP industrial Ethernet protocols, and the S7 200 SMART can also … Read more

Siemens 200smart Modbus RTU Communication Example

Siemens 200smart Modbus RTU Communication Example Communication Materials: 1) Two PLCs, namely the 200smart CR60 and SR20; 2) Two DP connectors (6ES7972-0BX12-0XA0) 3) Several connecting wires (for PLC power and communication) Verification Content: Set: CR60 PLC as the master station, sending the PLC system clock (8 bytes of information) to the SR20 slave station; the … Read more

Siemens S7-1200 PLC and V20 Inverter Modbus RTU Communication Case

Introduction In practical work sites, PLCs are often used to control inverters. There are several ways to control inverters via PLCs, such as terminal control, analog control, and communication control. Among these, communication control has certain advantages over the first two methods, such as being able to read multiple data from the inverter with just … Read more

20 Brand Inverter Modbus Communication Register Allocation Table

Search on WeChat Technical Training I have previously worked with microcontrollers and various models of inverters such as Mitsubishi D700, Siemens G120, Omron 3G3JZ, Panasonic VF200, Delta VFD-M, Xinjie VB3, Yonghong FID-B10, Chint IS7, Inovance MD500, Yaskawa Goodrive10, Schneider ATV12, Haiwei E, Holley HGD303, Taian F510, Hexin F2A, Rockwell PowerFlex-4, Fuji FRENIC-VP, Boke CV20, Yaskawa … Read more

Siemens S7-1200 PLC and V20 Inverter Modbus RTU Communication Case Study

Introduction In actual work sites, PLCs are often used to control inverters. There are several ways for PLC to control inverters, such as terminal control, analog control, and communication control. Among these, communication control has certain advantages over the first two methods, such as the ability to read multiple data from the inverter with just … Read more