How to Control Mitsubishi Inverters with Mitsubishi PLC via RS-485 Communication?

How to Control Mitsubishi Inverters with Mitsubishi PLC via RS-485 Communication?

Learn about PLC Using the PLC’s digital output to control the inverter (i.e., connecting the PLC’s digital output directly to the inverter’s digital input, allowing the PLC to control the inverter’s start, stop, forward, reverse, and multi-speed operation at high, medium, and low speeds through programming). Using the PLC’s analog signal to control the inverter. … Read more

What Are RS-485 and Modbus? Their Connection to IoT

What Are RS-485 and Modbus? Their Connection to IoT

Emmm… If you are a pure tech enthusiast wanting to continuously improve your skills want to learn more about IoT knowledge then we will introduce you to the following valuable information Principles and Application Scenarios of General Data Collectors The Differences and Connections between RS-485 and Modbus Understand in One Minute General Data Collector Application … Read more

Differences Between RS-485 and MODBUS

Differences Between RS-485 and MODBUS

Tip:Click above“Ba Fang Hui PLC Practical Programming Training“↑Follow us for free RS485is a wired transmission, which requires a hardware transmission medium, essentially just two wires are sufficient. The actual signal transmitted over these two wires is the same signal; the sending end splits this signal into two, but at the receiving end, it is restored … Read more

Detailed Explanation of RS-485 and MODBUS

Detailed Explanation of RS-485 and MODBUS

BFH Click the blue text to follow us↑↑↑↑ RS-485 is a wired transmission, so it requires a hardware transmission medium, which is essentially just two wires. The actual signal transmitted on these two wires is the same; the sender splits this signal into two, but at the receiving end, it is restored to its original … Read more

In-Depth Explanation of Common RS-485 Bus

In-Depth Explanation of Common RS-485 Bus

Past and Present RS-485, what does RS mean? It is an abbreviation for Recommended Standard, which means a recommended standard. 485 is the standard identification number, and there is no need to delve into why this identification number is set. RS-485 is also known as ANSI/TIA/EIA-485, these prefixes are abbreviations of standard associations’ names, for … Read more

Classic PLC Modbus Communication Case Study

Classic PLC Modbus Communication Case Study

1. Hardware Setup The Modbus communication in the program is conducted between the 0 communication ports of two S7-200 CPUs (it is best for each CPU to have two communication ports). On the master side, communication can also be established using the corresponding library files “MBUS_CTRL_P1” and “MBUS_MSG_P1” through the 1st communication port. Communication port … Read more

RS485 and Modbus Communication Protocol Tutorial

RS485 and Modbus Communication Protocol Tutorial

Search on WeChat Technical Training In 1979, Schneider Electric established a bus protocol for industrial sites called the Modbus protocol. Nowadays, many industrial applications using RS485 communication adopt the Modbus protocol. Today, we will explore RS485 communication and the Modbus communication protocol. 1. Introduction In fields such as industrial control, power communication, and smart instruments, … Read more

Sharing Knowledge on MODBUS Communication Between HMI and VFD (Part 2)

Sharing Knowledge on MODBUS Communication Between HMI and VFD (Part 2)

Here we continue to share knowledge about MODBUS communication between the HMI and the variable frequency drive (VFD).Previously, we discussed the two steps required to achieve communication between the HMI and the VFD: (1) Selection of communication driver in the HMI (2) Establishment of variables in the HMI Today, we will continue to share some … Read more

MODBUS Weight Instrument Communication with Siemens PLC

MODBUS Weight Instrument Communication with Siemens PLC

1 A weight instrument supporting the Modbus protocol A weight instrument supporting the Modbus protocol 2 Set the communication parameters of the instrument You can adjust according to your requirements, as long as it is consistent with the PLC side. Baud rate: 9600 Data format: 8n1: 8 data bits / no parity bit Communication method: … Read more

ABB Robot Modbus/TCP Communication

ABB Robot Modbus/TCP Communication

For more content, please click above to follow ABB Robot Practical Skills You can also click on the public account below Classic Articles to browse more content For reprints, please leave a message in the background first, let’s support original content together and promote the use and development of robots This public account provides technical … Read more