Step-By-Step Guide to Modbus Communication

Step-By-Step Guide to Modbus Communication

Search WeChat Electrical Engineering Learning This article will introduce the detailed steps of Modbus communication between the S7-1200 PLC and the V20 inverter. 1. Find an S7-1200 PLC with an RS485 communication module and a V20 inverter. 2. Connect the RS485 module to the V20 inverter. The wiring method is to connect the red wire … Read more

Detailed Guide on Building a Complete AGV Control System with S7-1200

Search on WeChat Technical Training Introduction This article introduces the implementation process of the Automated Guided Vehicle (AGV) control system, divided into hardware setup and software design. (1) Onboard Controller 1.1 Types of Onboard Controllers The onboard controller is the core of the control system and the entire AGV. So, which controller should be chosen? … Read more

Detailed Guide: Building a Complete AGV Control System with S7-1200

Detailed Guide: Building a Complete AGV Control System with S7-1200

This article introduces the implementation process of an Automated Guided Vehicle (AGV) control system, divided into hardware setup and software design. On-Board Controller 1.1 Types of On-Board Controllers The on-board controller is the core of the control system and the entire AGV. So which controller should be chosen? Based on the author’s experience, from a … Read more

Beginner’s Guide to TIA Portal: MODBUS TCP Client with S7-1200

Beginner's Guide to TIA Portal: MODBUS TCP Client with S7-1200

Hello everyone, good evening! Smart Control Education will officially go on holiday on February 29, 2022~ If you have any questions, you can add Xiao Zhi V: 18018269808 ; perhaps we haven’t met in person, but we have encountered each other online,Smart Control Education wishes everyone: Prosperity in 2022! What did Smart Control experience and … Read more

Siemens PLC Communication – Modbus RTU Communication – New Features of S7-1200 Modbus (RTU) Instructions V4

Siemens PLC Communication - Modbus RTU Communication - New Features of S7-1200 Modbus (RTU) Instructions V4

Hello everyone, good evening! How have you all been recently? Has the pandemic affected you in any way? Today is still a technical article: Siemens PLC Communication – Modbus RTU Communication – New Features of S7-1200 Modbus (RTU) Instructions V4. Modbus RTU Communication: S7-200 smart Modbus RTU master station communication (√) S7-200 smart Modbus RTU … Read more

Step-by-Step Guide to Siemens S7-1200 MODBUS RTU Communication with Temperature Controller and Inverter

Step-by-Step Guide to Siemens S7-1200 MODBUS RTU Communication with Temperature Controller and Inverter

Search on WeChat Technical Training 1. Hardware PLC 1. S7-1200 PLC 1211C model CM1241 communication module; 2. Panasonic temperature controller KT4-1; 3. Qixi inverter HD700 series; 4. MCGS TPC 7062K touch screen. 2. Communication Purpose PLC The S7-1200 PLC sets data for the temperature controller and inverter via the touch screen, including temperature setpoint (SV); … Read more

Overview of MODBUS TCP Communication with S7-1200 Integrated PN Interface

Overview of MODBUS TCP Communication with S7-1200 Integrated PN Interface

Overview of MODBUS TCP Communication with S7-1200 Integrated PN Interface Modbus TCP is a standard network communication protocol that communicates via TCP/IP through the PN interface on the CPU, eliminating the need for additional communication hardware modules. Modbus TCP uses open user communication connections as the communication path, supporting a maximum of 8 hybrid client … Read more

Example: MODBUS Communication Between Siemens S7-1200 and V20 Inverter

Example: MODBUS Communication Between Siemens S7-1200 and V20 Inverter

Search on WeChat Technical Training MODBUS Communication Between S7-1200 and V20 For MODBUS communication between S7-1200 and V20, the S7-1200 PLC needs to add a CM1241 RS485 communication module. 01 Communication Connection The V20 inverter is connected to the PLC via RS485 cable, using the standard MODBUS communication protocol. Through MODBUS communication, the PLC sends … Read more

S7-1200 MODBUS TCP Communication Multi-Request Handling

S7-1200 MODBUS TCP Communication Multi-Request Handling

S7-1200 MODBUS TCP Communication Multi-Request Handling Rules to be followed for individual client connections: 1. Each “MB_CLIENT” connection needs to use a different background data block; 2. Each “MB_CLIENT” connection must specify a server IP address; 3. Each “MB_CLIENT” connection must specify a unique connection ID; 4. Whether a unique IP port number is required … Read more

Key Points of Modbus-RTU Communication with S7-1200 CM1241

Key Points of Modbus-RTU Communication with S7-1200 CM1241

Recently, I used the S7-1200 to collect data from a certain flow sensor via Modbus-RTU. The Siemens side chose the CM1241 (RS422/485) (order number 6ES7 241-1CH32-0XB0, firmware version V2.2), and the CPU is 1214C with firmware version V4.2. I thought the debugging would be simple, but it took a lot of time, and I consulted … Read more