Variable Types and Data Processing in PLC Hardware Programming

Last week, I helped a colleague solve a problem with his temperature control system on the production line, which was frequently malfunctioning. After some investigation, it turned out that the variable type was not selected correctly, causing the decimal part to be truncated. This incident reminded me that we must discuss the topic of variable types and data processing in PLCs today; mastering this can help avoid at least 80% of logical errors in programming!

Variable Types and Data Processing in PLC Hardware Programming

PLC

Basic Variable Types in PLCs

In PLCs, variables can be understood as “containers” for data, and different containers can hold different types of information. The commonly used variable types include Bit (BOOL), Byte (BYTE), Word (WORD), Double Word (DWORD), Integer (INT), and Real (REAL). This might sound a bit abstract, so let me explain it differently:

A Bit (BOOL) is like a single-pole switch at home, which has only two states: on and off, corresponding to 1 and 0, and is most suitable for controlling motor start/stop and indicator lights. A Byte (BYTE) and a Word (WORD) are like cups of different capacities; a BYTE can store numbers from 0 to 255, while a WORD can store from 0 to 65535, making them suitable for storing count values, integer parts of temperatures, etc. A Real (REAL) is like a graduated measuring cup, which can be precise to the decimal point, making it suitable for handling data that requires high precision, such as temperature and pressure.

Variable Types and Data Processing in PLC Hardware Programming

1

Basic Operations in Data Processing

Now that we know about the “container” types, let’s look at how to “process” the data inside. The most common data processing operations in PLCs include arithmetic operations, comparison operations, data conversion, and data movement.

Arithmetic operations involve addition, subtraction, multiplication, and division, such as calculating production output or speed based on time. Comparison operations involve determining greater than, less than, or equal to, such as checking if the temperature exceeds a limit. Data conversion is like pouring water from a measuring cup into a bucket, such as converting REAL to INT or INT to DWORD. However, be cautious that converting from a “large container” to a “small container” may result in data loss, just like the temperature issue my colleague faced last week.

Variable Types and Data Processing in PLC Hardware Programming

2

Practical Experience in Choosing Variable Types

I remember a project I worked on two years ago involving an injection molding machine, where the system needed to precisely control the mold temperature. Initially, I used INT to store the temperature, but the control was inaccurate. Later, I switched to REAL for storage, and the problem was immediately resolved. The golden rule for choosing variable types is: decide based on the actual range and precision requirements of the data.

For switch signals, BOOL is sufficient; for values within the range of 0-255, use BYTE; for values requiring decimal precision, use REAL; and for handling large integers, use DWORD. Remember, if the variable type is not chosen correctly, it can lead to inaccurate data or, in severe cases, system failure!

Variable Types and Data Processing in PLC Hardware Programming

3

A Small Case Study: Production Counting and Yield Calculation

Suppose we want to create a production statistics system that needs to record total output and the number of defective products, and calculate the yield in real-time. How should we choose the variable types here?

If we expect the total output and defective count to not exceed 65535, we can use WORD; if it might be larger, we need to use DWORD. The yield is a percentage that includes decimals, so we must use REAL. The calculation code might look like this:

Yield := INT_TO_REAL(TotalOutput – DefectiveCount) / INT_TO_REAL(TotalOutput) * 100.0;

Note that we used INT_TO_REAL conversion here to ensure that the division operation is performed in the real number domain, avoiding the issue of integer division truncating the decimal part. This detail is particularly important!

Variable Types and Data Processing in PLC Hardware Programming

4

Common Errors and Debugging Tips

Let’s talk about some of the most common “pits”: first, data overflow, for example, if you store 65536 in a WORD, which has a maximum of 65535, it will result in 0; second, type mismatch, such as assigning a BOOL variable to a WORD, which may cause inexplicable issues; third, not performing type conversion leading to precision loss.

When encountering data processing anomalies, first check the actual values of the variables in the monitoring table to see if they are within a reasonable range; then check for implicit type conversions; finally, check for calculation overflow. I have a habit of annotating key variables with their expected ranges and units in comments for easier maintenance later.

Variable Types and Data Processing in PLC Hardware Programming

5

Points to Note

Variable naming should be meaningful; for example, “Feed Motor Start Signal” is much more intuitive than “X1”. Different PLC brands may have variations in data types; Siemens, Mitsubishi, and Omron each have their own terminologies, but the basic concepts are consistent. Finally, be especially careful with variable handling related to safety, such as pressure and temperature limit protection; it is best to implement redundant checks.

Data processing is fundamental in PLC programming. Mastering this area can significantly enhance the stability of your programs! Next time, we can discuss how to use data blocks and structures to organize these variables more clearly and efficiently. Remember, first learn to correctly use different types of variables, then consider optimization and advanced techniques. Feel free to consult me anytime with questions!

Variable Types and Data Processing in PLC Hardware Programming