Advanced Methods for Integrating PROFIBUS PA Devices into TIA Portal

Advanced Methods for Integrating PROFIBUS PA Devices into TIA Portal

【Introduction】There are multiple methods for integrating PROFIBUS PA field devices into TIA Portal.The type of integration is determined by the communication standard used on the CPU interface.Two different communication standards can be used here: Ethernet-based PROFINET communication or the classic PROFIBUS DP master system. (1) Advanced Integration via Profinet PROFINET is now the standard in … Read more

PROFIBUS Fault Diagnosis

PROFIBUS Fault Diagnosis

Fault Diagnosis When S7-1200 communicates as a DP Master, the CPU does not stop and does not require downloading the organization block when a DP slave is lost. There are several methods for diagnosing faults in PROFIBUS DP: 1. Through the Indicator Lights on the Module The DIAG light on the front panel is green … Read more

Introduction to PROFIBUS Connection Debugging Cases

Introduction to PROFIBUS Connection Debugging Cases

PROFIBUS is an international, open, fieldbus standard that is independent of device manufacturers. The transmission speed can be selected from 9.6 kbaud to 12 Mbaud, and when the bus system starts, all devices connected to the bus should be set to the same speed. It is used for factory automation at the workshop level for … Read more

Understanding the Differences Between PROFINET and PROFIBUS

Understanding the Differences Between PROFINET and PROFIBUS

End Source: Reprinted from Siemens, copyright belongs to the original author. Recommended Articles[Example] Mitsubishi Practical Position Control Program Case (with Source Code)Weekly Report Issue 46 | A summary of common problems faced by many students with Siemens, get it now!Highly Practical for Industrial Control People (Part 1)Highly Practical for Industrial Control People (Part 2)[Example] Comprehensive … Read more

Understanding the Differences Between PROFINET and PROFIBUS

Understanding the Differences Between PROFINET and PROFIBUS

WeChat Search Technical Training HISTORY / Previous Recommendations Complete Question Bank for 2021 Electrical Beginner Exam (Includes Answers) Is Troubleshooting Inverters Difficult? Just One Click! Can You Brush Through All Electrical Exam Questions with One Click? This Tool Is a Must-Have! Which of the Five Major Electrical Drawing Software (CAD, Eplan, CADe_simu…) Do You Pick? … Read more

Diagnosing Nodes on Profibus DP Bus in Siemens S7-300 PLC Programming

Diagnosing Nodes on Profibus DP Bus in Siemens S7-300 PLC Programming

In Siemens automation systems, the use of the Profibus DP bus is very widespread. It is essential to diagnose running bus devices and detect faults during usage. Today, I will summarize these issues briefly, hoping that everyone can complete the diagnosis and monitoring of the DP bus after learning.When applying PROFIBUS-DP and SIMATIC S7 for … Read more

Profibus DP Bus Diagnostics in S7-300/400 PLC Programming

Profibus DP Bus Diagnostics in S7-300/400 PLC Programming

In Siemens automation systems, the use of the Profibus DP bus is very common. It is essential to diagnose and detect faults in the bus devices during operation. Today, I will summarize these issues briefly, hoping that after learning, everyone can complete the diagnostics and monitoring of the DP bus. When applying PROFIBUS-DP and SIMATIC … Read more

Ovation Profibus DP Fieldbus Configuration Tutorial

Ovation Profibus DP Fieldbus Configuration Tutorial

Welcome to follow “Thermal Control Circle” ID: rekongquan Spread thermal control knowledge, share technical essence! Editor: Lanling Wang Thermal Control Technology Group The world of thermal control is full of excitement. Welcome to join the “Thermal Control Circle” WeChat group and QQ group. How to join: 1. Official QQ group number 587444254 2. Official WeChat … Read more

How to Handle F01910 Fault in G120 Inverter with PROFIBUS DP

How to Handle F01910 Fault in G120 Inverter with PROFIBUS DP

Click the blue text “Xijia Transmission” to follow the official account! When using the CU240B-2 DP, CU240E-2 DP, CU230P-2 DP, and CU250S-2 DP control units, the inverter will trigger the F01910 fault if it does not receive a message from the PROFIBUS master station within the specified watchdog time. 1 Common Causes of Faults (1) … Read more