Example | Mitsubishi PLC Controls Inverter via RS485
Search on WeChat Technical Training Preparation Required hardware: Mitsubishi FX3G PLC, RS485 communication module (FX3G-485BD), one Inovance inverter, touch screen (MT6071IP). Required knowledge: PLC communication protocol, command sending, inverter communication parameter settings. Wiring The wiring is quite simple. Insert the FX3G-485-BD module into the PLC, short SDB and RDB, short SDA and RDA. Connect the … Read more