Controlling V90 via MODBUS-RTU Communication

Controlling V90 via MODBUS-RTU Communication

Communication Requirements and Functions: The firmware version of V90 is V1.05 and above; V90 communicates through the RS485 interface at the top of the drive’s front panel (no additional hardware required); Pin assignment of RS485; (Pin 3 and Pin 8) Parameters can be modified, such as speed/position/torque set values via ModBus; Parameters can be monitored, … Read more

Introduction and Example Programming of S7-200 SMART MODBUS Communication

Introduction and Example Programming of S7-200 SMART MODBUS Communication

Click on the “Technical Training” above and select “Top Official Account“ Over 160,000 industrial control professionals follow this WeChat platform: technical sharing, learning exchange, industrial control videos Detailed structure diagram of Siemens S7-200 SMART PLC 1. Siemens S7-200 SMART as Modbus Slave 1. Check the Micro/WIN SMART Modbus RTU Slave instruction library (Figure 1), which … Read more

Modbus Communication Register Allocation Table for 35 Inverters

Modbus Communication Register Allocation Table for 35 Inverters

NEWS TODAY I have previously worked with microcontrollers and various inverter models including Mitsubishi D700, Siemens G120, Omron 3G3JZ, Panasonic VF200, Delta VFD-M, Xinjie VB3, Yonghong FID-B10, Shindengen IS7, Inovance MD500, Yaskawa Goodrive10, Schneider ATV12, Haiwei E, Holip HGD303, Taian F510, HEC F2A, Rockwell PowerFlex-4, Fuji FRENIC-VP, Boke CV20, Yaskawa A1000, Weichuang Artrich-AR60T, etc., using … Read more

20 Types of PLC Component Numbering and Modbus Address Mapping Table

For More Exciting Content, Click to Follow “Daodao Education” I have previously worked with microcontrollers and the following 20 types of PLCs for Modbus RTU serial communication. Now, I would like to share the mapping table of these 20 PLC input, output, and register components to their corresponding Modbus addresses. Mitsubishi FX3G-40MR/ES-A, Siemens S7-200 CPU226 … Read more

Modbus ASCII Communication Between Schneider M241 and Delta Inverter

Modbus ASCII Communication Between Schneider M241 and Delta Inverter

WeChat Search Technical Training 1. Hardware and Software Preparation Wiring: A+ and SG+ short-circuited, B- and SG- short-circuited Exercise 1: Add device “ASCII_Manager” double-click “serial_line_2” for serial line settings, then double-click “ASCII_Manager” for Modbus configuration Exercise 2: Add device “ASCII_Manager” double-click “serial_line_2” for serial line settings, then double-click “ASCII_Manager” for Modbus configuration 2. Inverter Parameter … Read more

Knowledge Sharing on MODBUS Communication Between Touch Screens and Inverters (Part 2)

Knowledge Sharing on MODBUS Communication Between Touch Screens and Inverters (Part 2)

Click the ” Technical Training ” above to select “Pin to Top” 120,000+ followers on the industrial control WeChat platform: Technical sharing, learning exchange, industrial control videos Good evening everyone, today I will continue to share knowledge about MODBUS communication between touch screens and inverters. Previously, I shared two steps required for communication between a … Read more

Example: MODBUS Communication Between Siemens S7-1200 and V20 Inverter

Example: MODBUS Communication Between Siemens S7-1200 and V20 Inverter

Search on WeChat Technical Training MODBUS Communication Between S7-1200 and V20 For MODBUS communication between S7-1200 and V20, the S7-1200 PLC needs to add a CM1241 RS485 communication module. 01 Communication Connection The V20 inverter is connected to the PLC via RS485 cable, using the standard MODBUS communication protocol. Through MODBUS communication, the PLC sends … Read more

Siemens S7-200 PLC Modbus Communication Control Inverter (Part 1)

Siemens S7-200 PLC Modbus Communication Control Inverter (Part 1)

Click the ” Jicheng Training ” above, select “Pin Public Account“ 150,000+ industrial control professionals are following this WeChat platform: technical sharing, learning exchange, industrial control videos (1) Modbus Communication Modbus communication of S7-200: S7-200 only supports the Modbus RTU protocol and does not support the Modbus ASCII protocol; Modbus is a master/slave communication mode … Read more

Siemens S7-1500 PLC MODBUS Communication

Siemens S7-1500 PLC MODBUS Communication

S7-1500 MODBUS Communication MODBUS MASTER: First configure the hardware, as shown below: Then open OB1, and program, as shown below: First call the initialized block MODBUS COMMONLOAD Pin description: REQ: The command starts on the rising edge (0 to 1). PORT: After installing and configuring the CM, you can find the CM port value in … Read more

S7-1200 MODBUS TCP Communication Multi-Request Handling

S7-1200 MODBUS TCP Communication Multi-Request Handling

S7-1200 MODBUS TCP Communication Multi-Request Handling Rules to be followed for individual client connections: 1. Each “MB_CLIENT” connection needs to use a different background data block; 2. Each “MB_CLIENT” connection must specify a server IP address; 3. Each “MB_CLIENT” connection must specify a unique connection ID; 4. Whether a unique IP port number is required … Read more